Weighing indicator XK3190-C602 adopts 32-bits ARM processor of core Cortex M3 and high precision of ¡Æ-¡÷ A/D conversion technology. It displays to the conversion of weight signals. The max conversion speed is over 200 times/sec. This indicator can be composed to catchweigher, Automatic gravimetric filling instruments, etc. It is used in various fast speed and high precision requirement weighing control.
Standard Function: - Able to set digital filter intensity, A/D conversion speed. - Weighing data save, check and delete, protection in case of power off. - Real-time clock without effect on power. - Standard: 8 input, 2 of them can be high speed counting input, coder input or interrupt ( high speed reflection ) input; 8 output ( optional for relay box ). Be able to fix-quantity control of two materials for standard programme. - Input & output can be expanded, each IO expanding box can be expanded to 8 on/off input and 8 on/off output. The max. connection number of IO expanding box is four. Total quantity of IO is 40 input and 40 output. - 2 separate serial communication interface, one is RS232, another is RS232/RS422/RS485 for selection, with two communication ways by continuous sending or on command method. - Parallel/serial print interface, able to connect many kinds of printers. - Chinese/English weighing date, accumulation, batching material or calibration can be printed. - Optical isolation 20mA current loop scoreboard display interface. - Optical isolation 4-20mA/0-10V analog output ( optional ).
Technical Parameter: - Max. verified counts: n=3000 - Min. input signal voltage of verified counts e: 1¦ÌV - Input signal range: -15mV ¨C 15mV - Weighing load cell power supply DC: 5V; 80mA - Max. connection number of load cell: 4 at 350¦¸ - Load cell connection mode: 6 wire, auto compensation for long distance. - Display: main display with 6 digits LED, data height: 0.56 inch, accessory display with digits LED, data height: 0.4 inch, 23 status instruction lights. - With real time clock. Time and date can be displayed on the indicator panel. - Max. data storage: 8064 weighing data or 4032 time & weighing data - Scoreboard display interface: serial output, 20mA current loop signal - Communication interface: 2 serial RS232C. one can be set to be RS422/RS485, baud rate 600-57600 for selection. - Parallel print interface: able to connect with micro printer, wide-line printer model LT800, KX-P1121 or LQ1600K - Output: 8 optical isolation, open collector on/off output, be able to connect 8 relay box. - Input: 8 optical isolation input, input signal + 12 - + 24V DC - Input & output expand: able to connect 4 expanding module, each module including 8 optical isolation input and 9 optical isolation relay output. - Analog output: 1 photo electricity seclusion output. 4-20mA/0-5V/0-10V, three models for selection. - Power supply: 110-230V AC; 50/60 Hz - Operating temperature/humidity: 0¡ãC-40¡ãC; ¡Ü90%RH - Storage temperature/humidity: -20-50¡ãC; ¡Ü90%RH - Dimension of installation portiforium: 152¡Á77(mm) - Weight: around 0.8kg |